Glaukos Announces US FDA Approval of NDA Supplement Allowing for Re-Administration of iDose® TR
“We are pleased to announce this important labeling enhancement for iDose TR, which should help expand access for patients who may benefit from repeat treatment and provide physicians with greater flexibility in managing their glaucoma patients over time,” said
Under the updated labeling, physicians may now re-administer iDose TR more than once in patients who maintain a healthy cornea, as defined by corneal endothelial cell density parameters. In clinical studies, iDose TR has demonstrated a favorable long-term corneal safety profile, with no clinically significant corneal endothelial cell loss observed through three years across both the Phase 3 and Phase 2b studies. Additionally, results from the iDose TR exchange trial demonstrated a second administration of iDose TR and removal of the original iDose TR implant was safe and well-tolerated, with the second iDose TR demonstrating a favorable safety profile over a 12-month evaluation period.
iDose TR is a first-of-its-kind, long-duration, intracameral procedural pharmaceutical therapy designed to continuously deliver 24/7 therapeutic levels of a proprietary formulation of travoprost inside the eye for extended periods of time. iDose TR is intended to improve the standard of care by addressing the ubiquitous patient non-compliance issues and chronic side effects associated with topical glaucoma medications.
For more information about iDose TR and Full Prescribing Information, please visit www.iDoseTRhcp.com.
About
About iDose® TR (
iDose TR (travoprost intracameral implant) is a long duration prostaglandin analog approved for a single administration and indicated for the reduction of intraocular pressure (IOP) in patients with open-angle glaucoma (OAG) or ocular hypertension (OHT). Made from medical-grade titanium, iDose TR is implanted through the trabecular meshwork and back wall of Schlemm's canal, directly into scleral tissue. Once implanted, 75 mcg of a novel, preservative-free, proprietary formulation of travoprost continuously elutes into the anterior chamber via membrane-controlled diffusion, allowing for 24/7 release of medication.
Indication for Use: iDose TR (travoprost intracameral implant) is indicated for the reduction of intraocular pressure (IOP) in patients with open angle glaucoma (OAG) or ocular hypertension (OHT).
Dosage and Administration: For ophthalmic intracameral administration. The intracameral administration should be carried out under standard aseptic conditions.
Contraindications: iDose TR is contraindicated in patients with active or suspected ocular or periocular infections, patients with corneal endothelial cell dystrophy (e.g., Fuch’s Dystrophy, corneal guttatae), patients with prior corneal transplantation, or endothelial cell transplants (e.g., Descemet’s Stripping Automated Endothelial Keratoplasty [DSAEK]), patients with hypersensitivity to travoprost or to any other components of the product.
Warnings and Precautions: iDose TR should be used with caution in patients with narrow angles or other angle abnormalities. Monitor patients routinely to confirm the location of the iDose TR at the site of administration. Increased pigmentation of the iris can occur. Iris pigmentation is likely to be permanent.
Adverse Reactions: In controlled studies, the most common ocular adverse reactions reported in 2% to 6% of patients were increases in intraocular pressure, iritis, dry eye, visual field defects, eye pain, ocular hyperaemia, and reduced visual acuity.
Forward-Looking Statements
All statements other than statements of historical facts included in this press release that address activities, events, or developments that we expect, believe, or anticipate will or may occur in the future are forward-looking statements. Although we believe that we have a reasonable basis for forward-looking statements contained herein, we caution you that they are based on current expectations about future events affecting us and are subject to risks, uncertainties, and factors relating to our operations and business environment, all of which are difficult to predict and many of which are beyond our control, that may cause our actual results to differ materially from those expressed or implied by forward-looking statements in this press release. These potential risks and uncertainties include, without limitation, our ability to successfully commercialize our iDose TR and Epioxa therapies, our ability to continue to generate sales of our commercialized products and develop and commercialize additional products, and the level of utilization and achievement of the repeat treatment algorithm used for the re-administration of the iDose TR. These and other risks, uncertainties, and factors related to
View source version on businesswire.com: https://www.businesswire.com/news/home/20260128062505/en/